ANYDATA-RG-COAX U.S. military standards RG series coaxial cable
Structure
Conductor: Single or stranded fine copper (tinned) wires ,copper clad steel or copper clad aluminum
Insulation: Foamed polyethylene (PEF) or solid polyethylene (PES)
Shield: 100% coated Aluminum mylar Single-sided aluminum foil
(optional non-self-adhesive, single-sided self-adhesive aluminum foil, double-sided self-adhesive aluminum foil, non-self-adhesive double-sided aluminum foil, etc.)
(Tinned) copper shielding braid coverage of 85%
(Optional aluminum-magnesium alloy wire, copper clad aluminum wire, etc.)
Outer sheath of PVC mixture material (color can be customized according to customer requirements)
Characteristic
Meet the UL444 standard, standard UL13,UL1685 fire test, the NEC 800 NEC725
Comply with BS7211 and CENELEC HD22.9,according to IEC 60332-3-24
Non-hazardous substances, RoHS compliant
This product complies with the provisions of the EEC directive 73/23 (low-voltage procedures)of CE
CE certification, so that the cable can be used simultaneously in Europe and other North American markets.
Performance
Operating voltage: 300 V
Operating temperature range:
Movable Installation: - 5 ° C to +70 ° C fixed installation: -40 ° C to +70 ° C
Impedance: 75 ± 3Ω
Rated temperature: 70 ° C
Rated capacitance: 54 ± 3 pF / m
Velocity of Propagation: 85%
Return Loss (100 meters): 20db
Attenuation: 69Db/km